Steel and grout inside a block wall

A block wall gets its strength from the steel and grout inside it. The guideline spells out the basics.

This is an independent referral guide. It connects homeowners with independent providers and may receive compensation. It is not a licensed contractor and it does not do the work.

Steel

The guideline calls for deformed bars meeting ASTM A615 Grade 40, with laps of 40 bar diameters where one continuous bar cannot be used. It places one #4 bar lengthwise in a bond beam every 16 inches as the block is laid up.

Grout

The guideline sets grout at a minimum 2,000 psi and says all cells must be filled solid with grout and vibrated.

Lifts and cleanouts

It limits grout lifts to 6 feet and says cleanouts are required for grout pours over 5 feet in height.

Cement type

The guideline notes that plastic cement is not permitted in retaining walls in Seismic Design Category C, D, or E.

Why you care

These are covered by the pre grout inspection. Ask to see the result.